<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-17 22-37-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 4/5, 43 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 28 kHz 2805 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,8 dBr 1,97 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Montrealin sinfoniaorkesteri, Hutchins Timot "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 28 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/17 22.36.30 Total samples: 2805 Equivalent time: 0:02:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60 80
FM Scope MAX: 4,0 dBr MIN: -0,8 dBr AVE: 1,97 dBr % above 12,2 dBr: 0,0 Last value: 1,9 dBr (2026/01/17 22.36.29) 22.22 22.24 22.26 22.28 22.30 22.32 22.34 22.36 0 2 4 Pm [dBr]